Saferidge
 

Kingspan Saferidge
Greenfield Business Pk2
Holywell
Flintshire
CH8 7GJ

Tel: +44 (0) 1352 716100
Fax: +44 (0) 1352 710161
info@kingspansaferidge.com
www.kingspanpanels.com

 

Caution: Kingspan fall prevention systems
should only be installed
and inspected by
specialist roofing and cladding contractors or
fall prevention specialist

Kingspan Saferidge Specification

The Kingspan Saferidge System consists of a plastic coated steel or aluminium (powder coated) sheet, an isolating layer and a powder coated extruded aluminium section. The mobile eyebolt is manufactured from anodised aluminium extruded sections complete with stainless steel eye piece and ancillary parts, all running on plastic-covered roller bearings.

H39 Saferidge Safety System

To be read with Preliminaries / General Conditions

Saferidge Roof Apex Safety System

Guidance Note - Add to Roof Specification Section.

140 Metal Profiled Cladding

Add to standard clause.

Roof Safety Protection System. As clause H39.255

Fixing Saferidge Roof Apex Safety System

210 Structure

Check that the roof cladding is in a suitable state to receive the Kingspan Saferidge System before commencing fixing. Installer to confirm to Client Advisor, before work commences, any defects to the roof deck.

255 Horizontal Roof Safety Protection Systems

Manufacturer And Reference

Kingspan Saferidge
Greenfield Business Pk2
Holywell
Flintshire
CH8 7GJ

Tel: +44 (0) 1352 716100

Components

Kingspan Saferidge Safety System with CE Mark to European Patent No. 00593150 comprising a plastic coated steel sheet ridge section, isolating layer and powder coated extruded aluminium section complete with mobile eyebolt, all fixings and endstops and entry gate.

Finish / Colour

To be confirmed.

Fastening

To be fixed strictly in accordance with the directions, issued by Kingspan Saferidge and supplied with the system, all for use by the installer. (No other fastener may be used).

Delivery Timescale

To be advised.

Manufacturing Lead Times

Prior to agreeing the on site programme, the installer to obtain delivery dates for all components from Kingspan Saferidge.

410 Fixing Saferidge Generally

Install per manufacturers' written instruction, with the fasteners provided, including closing all joints as work proceeds to 2mm clearance gap.

Remove all drilling swarf, dust and any other foreign matter before finally fixing sheets into position.

Protect Kingspan Saferidge adequately during fixing and up to Practical Completion against mechanical damage, corrosion and disfigurement. Rectify any defects as quickly as practicable to minimise damage and nuisance.

Check fastenings on completion add adjust as necessary to ensure they are watertight and the Kingspan Saferidge System is secure.

420 Fastenings Generally

Shall be specified and supplied by the manufacturer with each assembly of components.

440 Type(S), Number And Location Of Fastenings

As determined by the Manufacturer.

460 Thermal Movement

Draw together track ends and compress gaskets fitted to provide 2mm gap between end of tracks.

470 Structural Movement Joints

Do not run the Kingspan Saferidge System over structural movements joints. Obtain specific advise from the Manufacturer.

510 Filler Pieces

Replacement filler pieces shall be obtained by the installer from the roof deck manufacturer to the specification as per drawing, issued by Kingspan Saferidge.

511 Ancillary Components

Supply travelling eyebolt(s), endstops, slope rope(s) and rope securing eye(s) as specified by Kingspan Saferidge to run on the Saferidge System and provide compliance with BSEN795.

570 Sealing Ends

Sealant - Type(s) recommended for the purpose by sheet manufacturer. Ensure continuity and effectiveness of weather seal, at end length of the Kingspan Saferidge System. Do not over compress, gasket joints. End cap flashing to be supplied by Kingspan Saferidge.

580 Warning Notices

Install warning notice with each endstop set as supplied by manufacturer, bearing the words "DO NOT REMOVE".

590 Alignment

Alignment of Kingspan Saferidge must take account of the adjacent workmanship of the roof deck construction to ensure all fastenings are securely driven.